Load Frequency Control for Hydropower Plants using PID Controller
Many development republics began to get rid of conventional energy and towards to use renewable energy like hydropower system, solar cells and wind turbines as soon as possible. Load Frequency Control (LFC) problem is coming to be the main topics for mentioning schemes due to not corresponding betwe...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universiti Teknikal Malaysia Melaka (UTeM)
2016
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/19529/ http://umpir.ump.edu.my/id/eprint/19529/ http://umpir.ump.edu.my/id/eprint/19529/1/fkee-2016-ali-Load%20Frequency%20Control%20for%20Hydropower.pdf |
id |
ump-19529 |
---|---|
recordtype |
eprints |
spelling |
ump-195292018-09-28T07:59:31Z http://umpir.ump.edu.my/id/eprint/19529/ Load Frequency Control for Hydropower Plants using PID Controller Hammid, Ali Thaeer Hojabri, Mojgan M. H., Sulaiman Abdalla, Ahmed N. Kadhim, Atheer A. TK Electrical engineering. Electronics Nuclear engineering Many development republics began to get rid of conventional energy and towards to use renewable energy like hydropower system, solar cells and wind turbines as soon as possible. Load Frequency Control (LFC) problem is coming to be the main topics for mentioning schemes due to not corresponding between main power system inputs such as change load demand and change in speed turbine settings. This paper illustrates a selftuning control of hydropower system that suggested and confirmed under Automatic Generation Control (AGC) in power scheme. The suggested power system involves one single area. The suggested self-tuning control system is employed in performing the automatic generation control for load frequency control request and compared it with conventional control structure. The power system dynamic modeling has regularly built in several essential parameters which have a significant influence According to frequency limitation. The main problem with all controllers is an exaggerated reaction to minor errors, producing the system to oscillate. The output response results for hydropower system obviously proved the benefit of using maximum load demand by tuning PID controller. Whereas, tuning PID controller has got properly more rapid output response and minimal overshoot. Universiti Teknikal Malaysia Melaka (UTeM) 2016 Article PeerReviewed application/pdf en cc_by http://umpir.ump.edu.my/id/eprint/19529/1/fkee-2016-ali-Load%20Frequency%20Control%20for%20Hydropower.pdf Hammid, Ali Thaeer and Hojabri, Mojgan and M. H., Sulaiman and Abdalla, Ahmed N. and Kadhim, Atheer A. (2016) Load Frequency Control for Hydropower Plants using PID Controller. Journal of Telecommunication, Electronic and Computer Engineering (JTEC), 8 (10). pp. 47-51. ISSN 2180-1843 http://journal.utem.edu.my/index.php/jtec/article/view/1370 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Malaysia Pahang |
building |
UMP Institutional Repository |
collection |
Online Access |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Hammid, Ali Thaeer Hojabri, Mojgan M. H., Sulaiman Abdalla, Ahmed N. Kadhim, Atheer A. Load Frequency Control for Hydropower Plants using PID Controller |
description |
Many development republics began to get rid of conventional energy and towards to use renewable energy like hydropower system, solar cells and wind turbines as soon as possible. Load Frequency Control (LFC) problem is coming to be the main topics for mentioning schemes due to not corresponding between main power system inputs such as change load demand and change in speed turbine settings. This paper illustrates a selftuning control of hydropower system that suggested and confirmed under Automatic Generation Control (AGC) in power scheme. The suggested power system involves one single area. The suggested self-tuning control system is employed in performing the automatic generation control for load frequency control request and compared it with conventional control structure. The power system dynamic modeling has regularly built in several essential parameters which have a significant influence According to frequency limitation. The main problem with all controllers is an exaggerated reaction to minor errors, producing the system to oscillate. The output response results for hydropower system obviously proved the benefit of using maximum load demand by tuning PID controller. Whereas, tuning PID controller has got properly more rapid output response and minimal overshoot. |
format |
Article |
author |
Hammid, Ali Thaeer Hojabri, Mojgan M. H., Sulaiman Abdalla, Ahmed N. Kadhim, Atheer A. |
author_facet |
Hammid, Ali Thaeer Hojabri, Mojgan M. H., Sulaiman Abdalla, Ahmed N. Kadhim, Atheer A. |
author_sort |
Hammid, Ali Thaeer |
title |
Load Frequency Control for Hydropower Plants using PID Controller |
title_short |
Load Frequency Control for Hydropower Plants using PID Controller |
title_full |
Load Frequency Control for Hydropower Plants using PID Controller |
title_fullStr |
Load Frequency Control for Hydropower Plants using PID Controller |
title_full_unstemmed |
Load Frequency Control for Hydropower Plants using PID Controller |
title_sort |
load frequency control for hydropower plants using pid controller |
publisher |
Universiti Teknikal Malaysia Melaka (UTeM) |
publishDate |
2016 |
url |
http://umpir.ump.edu.my/id/eprint/19529/ http://umpir.ump.edu.my/id/eprint/19529/ http://umpir.ump.edu.my/id/eprint/19529/1/fkee-2016-ali-Load%20Frequency%20Control%20for%20Hydropower.pdf |
first_indexed |
2023-09-18T22:27:54Z |
last_indexed |
2023-09-18T22:27:54Z |
_version_ |
1777416090180124672 |