Effect of ammonia / water ratio in the performance absorption chiller.

The main objective of this study is to determine the coefficient of performance (COP) for absorption chillers. By using a reversible Carnot cycle process the optimum coefficient of performance (COP) and ammonia/water ratio are obtained. Gas Absorption Refrigeration Unit (Model: RF 10) is a complete...

Full description

Bibliographic Details
Main Author: Kamarul Ariffin, Idris
Format: Undergraduates Project Papers
Language:English
Published: 2008
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/197/
http://umpir.ump.edu.my/id/eprint/197/1/Kamarul_Ariffin.pdf
id ump-197
recordtype eprints
spelling ump-1972015-03-03T06:01:54Z http://umpir.ump.edu.my/id/eprint/197/ Effect of ammonia / water ratio in the performance absorption chiller. Kamarul Ariffin, Idris TP Chemical technology The main objective of this study is to determine the coefficient of performance (COP) for absorption chillers. By using a reversible Carnot cycle process the optimum coefficient of performance (COP) and ammonia/water ratio are obtained. Gas Absorption Refrigeration Unit (Model: RF 10) is a complete laboratory bench top unit for the demonstration and analyze the performance on effect of ammonia/water ratio in performance for absorption chillers. In this experiment the refrigerant is anhydrous ammonia and the absorber is water. The ammonia/water ratios used are in the range of 5% to 30% ammonia in water base on volume percentage in the solution. 2008-05 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/197/1/Kamarul_Ariffin.pdf Kamarul Ariffin, Idris (2008) Effect of ammonia / water ratio in the performance absorption chiller. Faculty of Chemical & Natural Resources Engineering, Universiti Malaysia Pahang.
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TP Chemical technology
spellingShingle TP Chemical technology
Kamarul Ariffin, Idris
Effect of ammonia / water ratio in the performance absorption chiller.
description The main objective of this study is to determine the coefficient of performance (COP) for absorption chillers. By using a reversible Carnot cycle process the optimum coefficient of performance (COP) and ammonia/water ratio are obtained. Gas Absorption Refrigeration Unit (Model: RF 10) is a complete laboratory bench top unit for the demonstration and analyze the performance on effect of ammonia/water ratio in performance for absorption chillers. In this experiment the refrigerant is anhydrous ammonia and the absorber is water. The ammonia/water ratios used are in the range of 5% to 30% ammonia in water base on volume percentage in the solution.
format Undergraduates Project Papers
author Kamarul Ariffin, Idris
author_facet Kamarul Ariffin, Idris
author_sort Kamarul Ariffin, Idris
title Effect of ammonia / water ratio in the performance absorption chiller.
title_short Effect of ammonia / water ratio in the performance absorption chiller.
title_full Effect of ammonia / water ratio in the performance absorption chiller.
title_fullStr Effect of ammonia / water ratio in the performance absorption chiller.
title_full_unstemmed Effect of ammonia / water ratio in the performance absorption chiller.
title_sort effect of ammonia / water ratio in the performance absorption chiller.
publishDate 2008
url http://umpir.ump.edu.my/id/eprint/197/
http://umpir.ump.edu.my/id/eprint/197/1/Kamarul_Ariffin.pdf
first_indexed 2023-09-18T21:52:07Z
last_indexed 2023-09-18T21:52:07Z
_version_ 1777413839029010432