Arc flash analysis study in industry

Nowadays, hazard that associated with arc flash incident is increasing every year by year. The increasing of the incident has been brought to our attention. This study proposed so that it can help the industries to eliminate or at least reduce those hazards. Through the analysis of this project, the...

Full description

Bibliographic Details
Main Author: Harna, Elavarasu
Format: Undergraduates Project Papers
Language:English
English
English
English
Published: 2010
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/2051/
http://umpir.ump.edu.my/id/eprint/2051/
http://umpir.ump.edu.my/id/eprint/2051/1/Arc%20flash%20analysis%20study%20in%20industry%20%28Table%20of%20content%29.pdf
http://umpir.ump.edu.my/id/eprint/2051/2/Arc%20flash%20analysis%20study%20in%20industry%20%28Abstract%29.pdf
http://umpir.ump.edu.my/id/eprint/2051/3/Arc%20flash%20analysis%20study%20in%20industry%20%28Chapter%201%29.pdf
http://umpir.ump.edu.my/id/eprint/2051/5/Arc%20flash%20analysis%20study%20in%20industry%20%28References%29.pdf
id ump-2051
recordtype eprints
spelling ump-20512017-04-07T03:20:01Z http://umpir.ump.edu.my/id/eprint/2051/ Arc flash analysis study in industry Harna, Elavarasu TK Electrical engineering. Electronics Nuclear engineering Nowadays, hazard that associated with arc flash incident is increasing every year by year. The increasing of the incident has been brought to our attention. This study proposed so that it can help the industries to eliminate or at least reduce those hazards. Through the analysis of this project, the limitation for the arc flash occurs will be proved through the stimulation of the short circuit calculation and the boundary calculation by using the ETAP software. There are few steps that will be included, which is data collection process, develop single line diagram, arcing short circuit calculations and also flash protection boundary calculations. The workers in industries should take the harm of arc flash as a serious matter and be aware of arc flash. The expected result from this project will be the limitation that will be gain in the end of this project. The limitations of the protective boundary to control the arc flash in industries. The limitations of the protective boundary from the result are also to control the usage of Personal Protective Equipment (PPE). For each distance form a system or work place there will be a certain suitable level of PPE. The result will help to reduce harm and accident that happens in industries. The analysis of this project basically will be based on industrial field, where the data that used to do the analysis will be involving the industry site 2010-12 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/2051/1/Arc%20flash%20analysis%20study%20in%20industry%20%28Table%20of%20content%29.pdf application/pdf en http://umpir.ump.edu.my/id/eprint/2051/2/Arc%20flash%20analysis%20study%20in%20industry%20%28Abstract%29.pdf application/pdf en http://umpir.ump.edu.my/id/eprint/2051/3/Arc%20flash%20analysis%20study%20in%20industry%20%28Chapter%201%29.pdf application/pdf en http://umpir.ump.edu.my/id/eprint/2051/5/Arc%20flash%20analysis%20study%20in%20industry%20%28References%29.pdf Harna, Elavarasu (2010) Arc flash analysis study in industry. Faculty Of Electrical & Electronic Engineering, Universiti Malaysia Pahang. http://iportal.ump.edu.my/lib/item?id=chamo:55067&theme=UMP2
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
English
English
English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Harna, Elavarasu
Arc flash analysis study in industry
description Nowadays, hazard that associated with arc flash incident is increasing every year by year. The increasing of the incident has been brought to our attention. This study proposed so that it can help the industries to eliminate or at least reduce those hazards. Through the analysis of this project, the limitation for the arc flash occurs will be proved through the stimulation of the short circuit calculation and the boundary calculation by using the ETAP software. There are few steps that will be included, which is data collection process, develop single line diagram, arcing short circuit calculations and also flash protection boundary calculations. The workers in industries should take the harm of arc flash as a serious matter and be aware of arc flash. The expected result from this project will be the limitation that will be gain in the end of this project. The limitations of the protective boundary to control the arc flash in industries. The limitations of the protective boundary from the result are also to control the usage of Personal Protective Equipment (PPE). For each distance form a system or work place there will be a certain suitable level of PPE. The result will help to reduce harm and accident that happens in industries. The analysis of this project basically will be based on industrial field, where the data that used to do the analysis will be involving the industry site
format Undergraduates Project Papers
author Harna, Elavarasu
author_facet Harna, Elavarasu
author_sort Harna, Elavarasu
title Arc flash analysis study in industry
title_short Arc flash analysis study in industry
title_full Arc flash analysis study in industry
title_fullStr Arc flash analysis study in industry
title_full_unstemmed Arc flash analysis study in industry
title_sort arc flash analysis study in industry
publishDate 2010
url http://umpir.ump.edu.my/id/eprint/2051/
http://umpir.ump.edu.my/id/eprint/2051/
http://umpir.ump.edu.my/id/eprint/2051/1/Arc%20flash%20analysis%20study%20in%20industry%20%28Table%20of%20content%29.pdf
http://umpir.ump.edu.my/id/eprint/2051/2/Arc%20flash%20analysis%20study%20in%20industry%20%28Abstract%29.pdf
http://umpir.ump.edu.my/id/eprint/2051/3/Arc%20flash%20analysis%20study%20in%20industry%20%28Chapter%201%29.pdf
http://umpir.ump.edu.my/id/eprint/2051/5/Arc%20flash%20analysis%20study%20in%20industry%20%28References%29.pdf
first_indexed 2023-09-18T21:55:33Z
last_indexed 2023-09-18T21:55:33Z
_version_ 1777414054520815616