Hybrid of Eddy Current Probe Based on Permanent Magnet and GMR Sensor

The eddy current testing (ECT) is used to inspect a material to determine its properties without destroying its utility. The applications include detection of flaws in aircrafts, pipeline, etc. An ECT is a weak sensitivity to a subsurface defect. Applications of giant magnetic sensors (GMR) are incr...

Full description

Bibliographic Details
Main Authors: Faraj, Moneer A., Fahmi, Samsuri, Abdalla, Ahmed N.
Format: Article
Language:English
Published: Universiti Teknikal Malaysia Melaka (UTeM) 2018
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/20721/
http://umpir.ump.edu.my/id/eprint/20721/
http://umpir.ump.edu.my/id/eprint/20721/1/Hybrid%20of%20Eddy%20Current%20Probe%20Based%20on.pdf
id ump-20721
recordtype eprints
spelling ump-207212018-03-29T00:41:04Z http://umpir.ump.edu.my/id/eprint/20721/ Hybrid of Eddy Current Probe Based on Permanent Magnet and GMR Sensor Faraj, Moneer A. Fahmi, Samsuri Abdalla, Ahmed N. TK Electrical engineering. Electronics Nuclear engineering The eddy current testing (ECT) is used to inspect a material to determine its properties without destroying its utility. The applications include detection of flaws in aircrafts, pipeline, etc. An ECT is a weak sensitivity to a subsurface defect. Applications of giant magnetic sensors (GMR) are increasingly applied to the measurement of weak magnetic fields related to the currents they cause. In this paper, GMR sensor with magnet bar (permanent) is utilized. The proposed probe system is utilized to study the impact of the width and depth defect on the signal of eddy current testing. The maximum depth of flaw in a mild steel can be revealed by using this probe. The graph of the difference between the peak amplitude and the penetration depth of each slot of a different width of the two bands of mild steel shows the increase of the signal for each slot and flat above 3mm. The experimental result proves the inability of a PMGMR probe to detect a defect at a depth of 3mm on a surface defect. Universiti Teknikal Malaysia Melaka (UTeM) 2018-01 Article PeerReviewed application/pdf en cc_by http://umpir.ump.edu.my/id/eprint/20721/1/Hybrid%20of%20Eddy%20Current%20Probe%20Based%20on.pdf Faraj, Moneer A. and Fahmi, Samsuri and Abdalla, Ahmed N. (2018) Hybrid of Eddy Current Probe Based on Permanent Magnet and GMR Sensor. Journal of Telecommunication, Electronic and Computer Engineering (JTEC), 10 (1-2). pp. 7-11. ISSN 2180-1843 http://journal.utem.edu.my/index.php/jtec/article/view/3312
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Faraj, Moneer A.
Fahmi, Samsuri
Abdalla, Ahmed N.
Hybrid of Eddy Current Probe Based on Permanent Magnet and GMR Sensor
description The eddy current testing (ECT) is used to inspect a material to determine its properties without destroying its utility. The applications include detection of flaws in aircrafts, pipeline, etc. An ECT is a weak sensitivity to a subsurface defect. Applications of giant magnetic sensors (GMR) are increasingly applied to the measurement of weak magnetic fields related to the currents they cause. In this paper, GMR sensor with magnet bar (permanent) is utilized. The proposed probe system is utilized to study the impact of the width and depth defect on the signal of eddy current testing. The maximum depth of flaw in a mild steel can be revealed by using this probe. The graph of the difference between the peak amplitude and the penetration depth of each slot of a different width of the two bands of mild steel shows the increase of the signal for each slot and flat above 3mm. The experimental result proves the inability of a PMGMR probe to detect a defect at a depth of 3mm on a surface defect.
format Article
author Faraj, Moneer A.
Fahmi, Samsuri
Abdalla, Ahmed N.
author_facet Faraj, Moneer A.
Fahmi, Samsuri
Abdalla, Ahmed N.
author_sort Faraj, Moneer A.
title Hybrid of Eddy Current Probe Based on Permanent Magnet and GMR Sensor
title_short Hybrid of Eddy Current Probe Based on Permanent Magnet and GMR Sensor
title_full Hybrid of Eddy Current Probe Based on Permanent Magnet and GMR Sensor
title_fullStr Hybrid of Eddy Current Probe Based on Permanent Magnet and GMR Sensor
title_full_unstemmed Hybrid of Eddy Current Probe Based on Permanent Magnet and GMR Sensor
title_sort hybrid of eddy current probe based on permanent magnet and gmr sensor
publisher Universiti Teknikal Malaysia Melaka (UTeM)
publishDate 2018
url http://umpir.ump.edu.my/id/eprint/20721/
http://umpir.ump.edu.my/id/eprint/20721/
http://umpir.ump.edu.my/id/eprint/20721/1/Hybrid%20of%20Eddy%20Current%20Probe%20Based%20on.pdf
first_indexed 2023-09-18T22:30:03Z
last_indexed 2023-09-18T22:30:03Z
_version_ 1777416224916897792