Electrochemical biosensor for nitrite based on polyacrylic-graphene composite film with covalently immobilized hemoglobin

A new biosensor for the analysis of nitrite in food was developed based on hemoglobin (Hb) covalently immobilized on the succinimide functionalized poly(n-butyl acrylate)-graphene [poly(nBA)-rGO] composite film deposited on a carbon-paste screen-printed electrode (SPE). The immobilized Hb on the pol...

Full description

Bibliographic Details
Main Authors: Raja Zaidatul Akhmar, Raja Jamaluddin, Heng, Lee Yook, Tan, Ling Ling, K. F., Chong
Format: Article
Language:English
English
Published: MDPI 2018
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/23075/
http://umpir.ump.edu.my/id/eprint/23075/
http://umpir.ump.edu.my/id/eprint/23075/
http://umpir.ump.edu.my/id/eprint/23075/1/Electrochemical%20biosensor%20for%20nitrite%20based%20on%20polyacrylic-graphene%20composite%20film%20with%20covalently%20immobilized%20hemoglobin.pdf
http://umpir.ump.edu.my/id/eprint/23075/7/Electrochemical%20Biosensor%20for%20Nitrite%20Based%20on%20Polyacrylic-Graphene%20Composite%20Film%20with%20Covalently%20Immobilized%20Hemoglobin.pdf
id ump-23075
recordtype eprints
spelling ump-230752019-01-15T04:47:40Z http://umpir.ump.edu.my/id/eprint/23075/ Electrochemical biosensor for nitrite based on polyacrylic-graphene composite film with covalently immobilized hemoglobin Raja Zaidatul Akhmar, Raja Jamaluddin Heng, Lee Yook Tan, Ling Ling K. F., Chong Q Science (General) A new biosensor for the analysis of nitrite in food was developed based on hemoglobin (Hb) covalently immobilized on the succinimide functionalized poly(n-butyl acrylate)-graphene [poly(nBA)-rGO] composite film deposited on a carbon-paste screen-printed electrode (SPE). The immobilized Hb on the poly(nBA)-rGO conducting matrix exhibited electrocatalytic ability for the reduction of nitrite with significant enhancement in the reduction peak at −0.6 V versus Ag/AgCl reference electrode. Thus, direct determination of nitrite can be achieved by monitoring the cathodic peak current signal of the proposed polyacrylic-graphene hybrid film-based voltammetric nitrite biosensor. The nitrite biosensor exhibited a reproducible dynamic linear response range from 0.05–5 mg L−1 nitrite and a detection limit of 0.03 mg L−1. No significant interference was observed by potential interfering ions such as Ca2+, Na+, K+, NH4+, Mg2+, and NO3− ions. Analysis of nitrite in both raw and processed edible bird’s nest (EBN) samples demonstrated recovery of close to 100%. The covalent immobilization of Hb on poly(nBA)-rGO composite film has improved the performance of the electrochemical nitrite biosensor in terms of broader detection range, lower detection limit, and prolonged biosensor stability. MDPI 2018 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/23075/1/Electrochemical%20biosensor%20for%20nitrite%20based%20on%20polyacrylic-graphene%20composite%20film%20with%20covalently%20immobilized%20hemoglobin.pdf pdf en http://umpir.ump.edu.my/id/eprint/23075/7/Electrochemical%20Biosensor%20for%20Nitrite%20Based%20on%20Polyacrylic-Graphene%20Composite%20Film%20with%20Covalently%20Immobilized%20Hemoglobin.pdf Raja Zaidatul Akhmar, Raja Jamaluddin and Heng, Lee Yook and Tan, Ling Ling and K. F., Chong (2018) Electrochemical biosensor for nitrite based on polyacrylic-graphene composite film with covalently immobilized hemoglobin. Sensors, 18 (5). pp. 1-17. ISSN 1424-8220 https://doi.org/10.3390/s18051343 https://doi.org/10.3390/s18051343
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
English
topic Q Science (General)
spellingShingle Q Science (General)
Raja Zaidatul Akhmar, Raja Jamaluddin
Heng, Lee Yook
Tan, Ling Ling
K. F., Chong
Electrochemical biosensor for nitrite based on polyacrylic-graphene composite film with covalently immobilized hemoglobin
description A new biosensor for the analysis of nitrite in food was developed based on hemoglobin (Hb) covalently immobilized on the succinimide functionalized poly(n-butyl acrylate)-graphene [poly(nBA)-rGO] composite film deposited on a carbon-paste screen-printed electrode (SPE). The immobilized Hb on the poly(nBA)-rGO conducting matrix exhibited electrocatalytic ability for the reduction of nitrite with significant enhancement in the reduction peak at −0.6 V versus Ag/AgCl reference electrode. Thus, direct determination of nitrite can be achieved by monitoring the cathodic peak current signal of the proposed polyacrylic-graphene hybrid film-based voltammetric nitrite biosensor. The nitrite biosensor exhibited a reproducible dynamic linear response range from 0.05–5 mg L−1 nitrite and a detection limit of 0.03 mg L−1. No significant interference was observed by potential interfering ions such as Ca2+, Na+, K+, NH4+, Mg2+, and NO3− ions. Analysis of nitrite in both raw and processed edible bird’s nest (EBN) samples demonstrated recovery of close to 100%. The covalent immobilization of Hb on poly(nBA)-rGO composite film has improved the performance of the electrochemical nitrite biosensor in terms of broader detection range, lower detection limit, and prolonged biosensor stability.
format Article
author Raja Zaidatul Akhmar, Raja Jamaluddin
Heng, Lee Yook
Tan, Ling Ling
K. F., Chong
author_facet Raja Zaidatul Akhmar, Raja Jamaluddin
Heng, Lee Yook
Tan, Ling Ling
K. F., Chong
author_sort Raja Zaidatul Akhmar, Raja Jamaluddin
title Electrochemical biosensor for nitrite based on polyacrylic-graphene composite film with covalently immobilized hemoglobin
title_short Electrochemical biosensor for nitrite based on polyacrylic-graphene composite film with covalently immobilized hemoglobin
title_full Electrochemical biosensor for nitrite based on polyacrylic-graphene composite film with covalently immobilized hemoglobin
title_fullStr Electrochemical biosensor for nitrite based on polyacrylic-graphene composite film with covalently immobilized hemoglobin
title_full_unstemmed Electrochemical biosensor for nitrite based on polyacrylic-graphene composite film with covalently immobilized hemoglobin
title_sort electrochemical biosensor for nitrite based on polyacrylic-graphene composite film with covalently immobilized hemoglobin
publisher MDPI
publishDate 2018
url http://umpir.ump.edu.my/id/eprint/23075/
http://umpir.ump.edu.my/id/eprint/23075/
http://umpir.ump.edu.my/id/eprint/23075/
http://umpir.ump.edu.my/id/eprint/23075/1/Electrochemical%20biosensor%20for%20nitrite%20based%20on%20polyacrylic-graphene%20composite%20film%20with%20covalently%20immobilized%20hemoglobin.pdf
http://umpir.ump.edu.my/id/eprint/23075/7/Electrochemical%20Biosensor%20for%20Nitrite%20Based%20on%20Polyacrylic-Graphene%20Composite%20Film%20with%20Covalently%20Immobilized%20Hemoglobin.pdf
first_indexed 2023-09-18T22:34:26Z
last_indexed 2023-09-18T22:34:26Z
_version_ 1777416500810874880