Designing a new concept of LC-DCP broad type bone plate

Bone plate design has evolved dramatically in recent years. The main research of the study is to improve the previous design of the Dynamic Compression Plate (DCP) broad type bone plates that was used in bone fracture as internal fixation. The DCP bone plate has been superseded by new plating system...

Full description

Bibliographic Details
Main Author: Muhammad Kamal Asyraf, Pubin
Format: Undergraduates Project Papers
Language:English
Published: 2007
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/2325/
http://umpir.ump.edu.my/id/eprint/2325/
http://umpir.ump.edu.my/id/eprint/2325/1/MUHAMMAD_KAMAL_ASYRAF_BIN_PUBIN.PDF
id ump-2325
recordtype eprints
spelling ump-23252015-03-03T07:55:56Z http://umpir.ump.edu.my/id/eprint/2325/ Designing a new concept of LC-DCP broad type bone plate Muhammad Kamal Asyraf, Pubin RD Surgery Bone plate design has evolved dramatically in recent years. The main research of the study is to improve the previous design of the Dynamic Compression Plate (DCP) broad type bone plates that was used in bone fracture as internal fixation. The DCP bone plate has been superseded by new plating system that claim a reduced interface contact between the plate and the underlying bone. It is believed that contact reduction can reduce the risk of Ischaemia - deficiency of blood in a part, usually due to functional constriction or actual obstruction of blood vessel that could lead to other side effect on the patient. To develop the new proposed design, CAD (Computer Aided Design) software is used to design and simulate the model. The interface characteristics of the actual Dynamic Compression Plate (DCP) and the new Low-Contact Dynamic Compression Plate (LC-DCP) plating systems have been analyzed using a Finite Element Analysis (FEA) software. The final result of model simulation is displayed in form of stress von Mises, and heat transfer distribution. The maximum value of von-Mises stress for the new LC-DCP is 768195.2 N/rn 2 and heat transfer distribution temperature is 57.15 °C. The LC-DCP system was consistently lower, in terms of interface contact, than the DCP in each of the CAD model tested. 2007-11 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/2325/1/MUHAMMAD_KAMAL_ASYRAF_BIN_PUBIN.PDF Muhammad Kamal Asyraf, Pubin (2007) Designing a new concept of LC-DCP broad type bone plate. Faculty of Mechanical Engineering, Universiti Malaysia Pahang. http://iportal.ump.edu.my/lib/item?id=chamo:30989&theme=UMP2
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic RD Surgery
spellingShingle RD Surgery
Muhammad Kamal Asyraf, Pubin
Designing a new concept of LC-DCP broad type bone plate
description Bone plate design has evolved dramatically in recent years. The main research of the study is to improve the previous design of the Dynamic Compression Plate (DCP) broad type bone plates that was used in bone fracture as internal fixation. The DCP bone plate has been superseded by new plating system that claim a reduced interface contact between the plate and the underlying bone. It is believed that contact reduction can reduce the risk of Ischaemia - deficiency of blood in a part, usually due to functional constriction or actual obstruction of blood vessel that could lead to other side effect on the patient. To develop the new proposed design, CAD (Computer Aided Design) software is used to design and simulate the model. The interface characteristics of the actual Dynamic Compression Plate (DCP) and the new Low-Contact Dynamic Compression Plate (LC-DCP) plating systems have been analyzed using a Finite Element Analysis (FEA) software. The final result of model simulation is displayed in form of stress von Mises, and heat transfer distribution. The maximum value of von-Mises stress for the new LC-DCP is 768195.2 N/rn 2 and heat transfer distribution temperature is 57.15 °C. The LC-DCP system was consistently lower, in terms of interface contact, than the DCP in each of the CAD model tested.
format Undergraduates Project Papers
author Muhammad Kamal Asyraf, Pubin
author_facet Muhammad Kamal Asyraf, Pubin
author_sort Muhammad Kamal Asyraf, Pubin
title Designing a new concept of LC-DCP broad type bone plate
title_short Designing a new concept of LC-DCP broad type bone plate
title_full Designing a new concept of LC-DCP broad type bone plate
title_fullStr Designing a new concept of LC-DCP broad type bone plate
title_full_unstemmed Designing a new concept of LC-DCP broad type bone plate
title_sort designing a new concept of lc-dcp broad type bone plate
publishDate 2007
url http://umpir.ump.edu.my/id/eprint/2325/
http://umpir.ump.edu.my/id/eprint/2325/
http://umpir.ump.edu.my/id/eprint/2325/1/MUHAMMAD_KAMAL_ASYRAF_BIN_PUBIN.PDF
first_indexed 2023-09-18T21:56:01Z
last_indexed 2023-09-18T21:56:01Z
_version_ 1777414084250042368