ECG noise reduction technique using Antlion Optimizer (ALO) for heart rate monitoring devices

The electrocardiogram (ECG) signal is susceptible to noise and artifacts and it is essential to remove the noise in order to support any decision making for specialist and automatic heart disorder diagnosis systems. In this paper, the use of Antlion Optimization (ALO) for optimizing and identifying...

Full description

Bibliographic Details
Main Authors: Hii, Kiew Hui, Narayanamurthy, Vigneswaran, Fahmi, Samsuri
Format: Article
Language:English
Published: ETASR 2019
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/25317/
http://umpir.ump.edu.my/id/eprint/25317/
http://umpir.ump.edu.my/id/eprint/25317/7/ECG%20noise%20reduction%20technique%20using%20Antlion%20Optimizer.pdf
id ump-25317
recordtype eprints
spelling ump-253172019-10-08T01:34:09Z http://umpir.ump.edu.my/id/eprint/25317/ ECG noise reduction technique using Antlion Optimizer (ALO) for heart rate monitoring devices Hii, Kiew Hui Narayanamurthy, Vigneswaran Fahmi, Samsuri TK Electrical engineering. Electronics Nuclear engineering The electrocardiogram (ECG) signal is susceptible to noise and artifacts and it is essential to remove the noise in order to support any decision making for specialist and automatic heart disorder diagnosis systems. In this paper, the use of Antlion Optimization (ALO) for optimizing and identifying the cutoff frequercy of ECG signal for low-pass filtering is investigated. Generally, the spectrums of the ECG signal are extracted from two classes: arrhythmia and supraventricular. Baseline wander is removed using the moving median filter. A dataset of the extracted features of the ECG spectrums is used to train the ALO. The performance of the ALO with various parameters is investigated. The ALO-identified cutoff frequency is applied to a Finite Impulse Response (FIR) filter and the resulting signal is evaluated against the original clean and conventional filtered ECG signals. The results show that the intelligent AL0-based system successfully denoised the ECG signals more effectively than the conventional method. The percentage of the accuracy increased by 2%. ETASR 2019 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/25317/7/ECG%20noise%20reduction%20technique%20using%20Antlion%20Optimizer.pdf Hii, Kiew Hui and Narayanamurthy, Vigneswaran and Fahmi, Samsuri (2019) ECG noise reduction technique using Antlion Optimizer (ALO) for heart rate monitoring devices. Engineering Technology & Applied Science Research, 9 (4). pp. 4525-4529. ISSN 1792-8036 https://www.etasr.com/index.php/ETASR/article/view/2766
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Hii, Kiew Hui
Narayanamurthy, Vigneswaran
Fahmi, Samsuri
ECG noise reduction technique using Antlion Optimizer (ALO) for heart rate monitoring devices
description The electrocardiogram (ECG) signal is susceptible to noise and artifacts and it is essential to remove the noise in order to support any decision making for specialist and automatic heart disorder diagnosis systems. In this paper, the use of Antlion Optimization (ALO) for optimizing and identifying the cutoff frequercy of ECG signal for low-pass filtering is investigated. Generally, the spectrums of the ECG signal are extracted from two classes: arrhythmia and supraventricular. Baseline wander is removed using the moving median filter. A dataset of the extracted features of the ECG spectrums is used to train the ALO. The performance of the ALO with various parameters is investigated. The ALO-identified cutoff frequency is applied to a Finite Impulse Response (FIR) filter and the resulting signal is evaluated against the original clean and conventional filtered ECG signals. The results show that the intelligent AL0-based system successfully denoised the ECG signals more effectively than the conventional method. The percentage of the accuracy increased by 2%.
format Article
author Hii, Kiew Hui
Narayanamurthy, Vigneswaran
Fahmi, Samsuri
author_facet Hii, Kiew Hui
Narayanamurthy, Vigneswaran
Fahmi, Samsuri
author_sort Hii, Kiew Hui
title ECG noise reduction technique using Antlion Optimizer (ALO) for heart rate monitoring devices
title_short ECG noise reduction technique using Antlion Optimizer (ALO) for heart rate monitoring devices
title_full ECG noise reduction technique using Antlion Optimizer (ALO) for heart rate monitoring devices
title_fullStr ECG noise reduction technique using Antlion Optimizer (ALO) for heart rate monitoring devices
title_full_unstemmed ECG noise reduction technique using Antlion Optimizer (ALO) for heart rate monitoring devices
title_sort ecg noise reduction technique using antlion optimizer (alo) for heart rate monitoring devices
publisher ETASR
publishDate 2019
url http://umpir.ump.edu.my/id/eprint/25317/
http://umpir.ump.edu.my/id/eprint/25317/
http://umpir.ump.edu.my/id/eprint/25317/7/ECG%20noise%20reduction%20technique%20using%20Antlion%20Optimizer.pdf
first_indexed 2023-09-18T22:38:49Z
last_indexed 2023-09-18T22:38:49Z
_version_ 1777416776558051328