Study on effective parameter of the triple-pressure reheat combined cycle performance

The thermodynamic analyses of the triple-pressure reheat combined cycle gas turbines with duct burner are presented and discussed in this paper. The overall performance of a combined cycle gas turbine power plant is influenced by the ambient temperature, compression ratio and turbine inlet temperatu...

Full description

Bibliographic Details
Main Authors: Thamir K., Ibrahim, M. M., Rahman
Format: Article
Language:English
Published: Thermal Science 2013
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/25355/
http://umpir.ump.edu.my/id/eprint/25355/
http://umpir.ump.edu.my/id/eprint/25355/
http://umpir.ump.edu.my/id/eprint/25355/1/Study%20on%20effective%20parameter%20of%20the%20triple-pressure%20reheat%20combined%20cycle%20performance.pdf
id ump-25355
recordtype eprints
spelling ump-253552019-12-10T01:17:15Z http://umpir.ump.edu.my/id/eprint/25355/ Study on effective parameter of the triple-pressure reheat combined cycle performance Thamir K., Ibrahim M. M., Rahman TJ Mechanical engineering and machinery The thermodynamic analyses of the triple-pressure reheat combined cycle gas turbines with duct burner are presented and discussed in this paper. The overall performance of a combined cycle gas turbine power plant is influenced by the ambient temperature, compression ratio and turbine inlet temperature. These parameters affect the overall thermal efficiency, power output and the heat-rate. In this study a thermodynamic model was development on an existing actual combined cycle gas turbine (CCGT) (In this case study, an effort has been made to enhance the performance of the CCGT through a parametric study using a thermodynamic analysis. The effect of ambient temperature and operation parameter, including compression ratio and turbine inlet temperature, on the overall performance of CCGT are investigated. The code of the performance model for CCGT power plant was developed utilizing the THERMOFLEX software. The simulating results show that the total power output and overall efficiency of a CCGT decrease with increase the ambient temperature because increase the consumption power in the air compressor of a GT. The totals power of a CCGT decreases with increase the compression rate, while the overall efficiency of a CCGT increases with increase the compression ratio to 21, after that the overall efficiency will go down. Far there more the turbine inlet temperature increases the both total power and overall efficiency increase, so the turbine inlet temperature has a strong effect on the overall performance of CCGT power plant. Also the simulation model give a good result compared with MARAFIQ CCGT power plant. With these variables, the turbine inlet temperature causes the greatest overall performance variation. Thermal Science 2013 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/25355/1/Study%20on%20effective%20parameter%20of%20the%20triple-pressure%20reheat%20combined%20cycle%20performance.pdf Thamir K., Ibrahim and M. M., Rahman (2013) Study on effective parameter of the triple-pressure reheat combined cycle performance. Thermal Science, 17 (2). pp. 497-508. ISSN 2334-7163 https://doi.org/10.2298/TSCI111016143I https://doi.org/10.2298/TSCI111016143I
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Thamir K., Ibrahim
M. M., Rahman
Study on effective parameter of the triple-pressure reheat combined cycle performance
description The thermodynamic analyses of the triple-pressure reheat combined cycle gas turbines with duct burner are presented and discussed in this paper. The overall performance of a combined cycle gas turbine power plant is influenced by the ambient temperature, compression ratio and turbine inlet temperature. These parameters affect the overall thermal efficiency, power output and the heat-rate. In this study a thermodynamic model was development on an existing actual combined cycle gas turbine (CCGT) (In this case study, an effort has been made to enhance the performance of the CCGT through a parametric study using a thermodynamic analysis. The effect of ambient temperature and operation parameter, including compression ratio and turbine inlet temperature, on the overall performance of CCGT are investigated. The code of the performance model for CCGT power plant was developed utilizing the THERMOFLEX software. The simulating results show that the total power output and overall efficiency of a CCGT decrease with increase the ambient temperature because increase the consumption power in the air compressor of a GT. The totals power of a CCGT decreases with increase the compression rate, while the overall efficiency of a CCGT increases with increase the compression ratio to 21, after that the overall efficiency will go down. Far there more the turbine inlet temperature increases the both total power and overall efficiency increase, so the turbine inlet temperature has a strong effect on the overall performance of CCGT power plant. Also the simulation model give a good result compared with MARAFIQ CCGT power plant. With these variables, the turbine inlet temperature causes the greatest overall performance variation.
format Article
author Thamir K., Ibrahim
M. M., Rahman
author_facet Thamir K., Ibrahim
M. M., Rahman
author_sort Thamir K., Ibrahim
title Study on effective parameter of the triple-pressure reheat combined cycle performance
title_short Study on effective parameter of the triple-pressure reheat combined cycle performance
title_full Study on effective parameter of the triple-pressure reheat combined cycle performance
title_fullStr Study on effective parameter of the triple-pressure reheat combined cycle performance
title_full_unstemmed Study on effective parameter of the triple-pressure reheat combined cycle performance
title_sort study on effective parameter of the triple-pressure reheat combined cycle performance
publisher Thermal Science
publishDate 2013
url http://umpir.ump.edu.my/id/eprint/25355/
http://umpir.ump.edu.my/id/eprint/25355/
http://umpir.ump.edu.my/id/eprint/25355/
http://umpir.ump.edu.my/id/eprint/25355/1/Study%20on%20effective%20parameter%20of%20the%20triple-pressure%20reheat%20combined%20cycle%20performance.pdf
first_indexed 2023-09-18T22:38:53Z
last_indexed 2023-09-18T22:38:53Z
_version_ 1777416780687343616