Effect of excitation frequency on magnetic response induced by front-and back-side slits measured by a differential AMR sensor probe

Defects in steel structures is one of the major problems that may affect the functionality of the structure. Thus, the detection of the defects is fairly crucial to prevent any unwanted accident from occurring. Nondestructive Testing (NDT) is a group of methods that is widely used in order to detect...

Full description

Bibliographic Details
Main Authors: M. A. H., P. Zaini, M. M., Saari, Nurul A’in, Nadzri, A. M., Halil, A. J., S. Hanifah, M., Ishak
Format: Conference or Workshop Item
Language:English
English
Published: Universiti Malaysia Pahang 2019
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/26966/
http://umpir.ump.edu.my/id/eprint/26966/1/98.%20Effect%20of%20excitation%20frequency%20on%20magnetic%20response%20induced.pdf
http://umpir.ump.edu.my/id/eprint/26966/2/98.1%20Effect%20of%20excitation%20frequency%20on%20magnetic%20response%20induced.pdf
Description
Summary:Defects in steel structures is one of the major problems that may affect the functionality of the structure. Thus, the detection of the defects is fairly crucial to prevent any unwanted accident from occurring. Nondestructive Testing (NDT) is a group of methods that is widely used in order to detect those defects, especially cracks. This paper will be focusing on the detection of cracks (artificial slits) by using the Magnetic Flux Leakage (MFL) technique in the magnetic method of NDT. A non-saturated differential MFL probe consists of two AMR sensors has been fabricated for the detection of front and back side slits. A measurement system which incorporates the developed probe attached on an XY-stage, an amplifier circuit, a set/reset circuit, a DAQ card and PC is constructed where an XY-stage controller and a digital lock-in amplifier are developed via LabVIEW. Then, the performance of the developed MFL probe is evaluated by running a number of line scan measurements on a 2-mm galvanized steel plate sample engraved with artificial slits with variable depths ranging from 1.0 mm to 1.6 mm with variable excited frequencies. The results show promising output where the slits could be successfully detected and its position could be further estimated. Furthermore, the correlation between the slit depth and difference (delta) between the signal peaks and troughs could also be founded. Consequently, the optimum excitation frequency can be determined by plotting a graph of slope of trendline of the delta values versus the frequency.