Variable speed pump performance characteristics for domestic application
Generally, water pumps work at a fixed speed. Structural resonance in fixed speed can cause vibration. The reason that most single speed pumps utilize an excessive amount of electricity is that they are overused and oversized. Therefore, this research is embarked to study the characteristic of a pre...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2018
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/27718/ http://umpir.ump.edu.my/id/eprint/27718/ http://umpir.ump.edu.my/id/eprint/27718/ http://umpir.ump.edu.my/id/eprint/27718/1/matecconf_ses2018_02005.pdf |
id |
ump-27718 |
---|---|
recordtype |
eprints |
spelling |
ump-277182020-02-07T02:23:19Z http://umpir.ump.edu.my/id/eprint/27718/ Variable speed pump performance characteristics for domestic application Siti Aisyah, Jilani Akhtar Razul, Razali T Technology (General) TJ Mechanical engineering and machinery Generally, water pumps work at a fixed speed. Structural resonance in fixed speed can cause vibration. The reason that most single speed pumps utilize an excessive amount of electricity is that they are overused and oversized. Therefore, this research is embarked to study the characteristic of a pressure-controlled variable speed pump, develop the variable speed pressure controlled pump and analyse the pump performance. A technique is proposed to change the constant speed pump to variable speed pump by adding Variable Frequency Drive (VFD) and microcontroller. A simple test rig is designed and fabricated represented of water distribution for domestic use. The method was then experimentally validated to verify the pump performance and energy used. Data for water flow rate, water pressure, power output and pump speed were analysed. Since the speed can be lowered until 29.27% which according to the water volume demands, therefore the power consumption was found decreased and the lowest power is 0.014 kW. Maximum water discharge capability is 32.38 lpm. It is found that, a variable speed water pump able to save energy up to 97% and led to electricity bill saving and increase the life span of pipes and joints through less hydraulic pressure built-up. EDP Sciences 2018 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/27718/1/matecconf_ses2018_02005.pdf Siti Aisyah, Jilani and Akhtar Razul, Razali (2018) Variable speed pump performance characteristics for domestic application. MATEC Web of Conferences 225, 02005 (2018), 225 (2005). ISSN eISSN: 2261-236X https://www.matec-conferences.org/articles/matecconf/abs/2018/84/matecconf_ses2018_02005/matecconf_ses2018_02005.html https://doi.org/10.1051/matecconf/201822502005 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Malaysia Pahang |
building |
UMP Institutional Repository |
collection |
Online Access |
language |
English |
topic |
T Technology (General) TJ Mechanical engineering and machinery |
spellingShingle |
T Technology (General) TJ Mechanical engineering and machinery Siti Aisyah, Jilani Akhtar Razul, Razali Variable speed pump performance characteristics for domestic application |
description |
Generally, water pumps work at a fixed speed. Structural resonance in fixed speed can cause vibration. The reason that most single speed pumps utilize an excessive amount of electricity is that they are overused and oversized. Therefore, this research is embarked to study the characteristic of a pressure-controlled variable speed pump, develop the variable speed pressure controlled pump and analyse the pump performance. A technique is proposed to change the constant speed pump to variable speed pump by adding Variable Frequency Drive (VFD) and microcontroller. A simple test rig is designed and fabricated represented of water distribution for domestic use. The method was then experimentally validated to verify the pump performance and energy used. Data for water flow rate, water pressure, power output and pump speed were analysed. Since the speed can be lowered until 29.27% which according to the water volume demands, therefore the power consumption was found decreased and the lowest power is 0.014 kW. Maximum water discharge capability is 32.38 lpm. It is found that, a variable speed water pump able to save energy up to 97% and led to electricity bill saving and increase the life span of pipes and joints through less hydraulic pressure built-up. |
format |
Article |
author |
Siti Aisyah, Jilani Akhtar Razul, Razali |
author_facet |
Siti Aisyah, Jilani Akhtar Razul, Razali |
author_sort |
Siti Aisyah, Jilani |
title |
Variable speed pump performance characteristics for domestic application |
title_short |
Variable speed pump performance characteristics for domestic application |
title_full |
Variable speed pump performance characteristics for domestic application |
title_fullStr |
Variable speed pump performance characteristics for domestic application |
title_full_unstemmed |
Variable speed pump performance characteristics for domestic application |
title_sort |
variable speed pump performance characteristics for domestic application |
publisher |
EDP Sciences |
publishDate |
2018 |
url |
http://umpir.ump.edu.my/id/eprint/27718/ http://umpir.ump.edu.my/id/eprint/27718/ http://umpir.ump.edu.my/id/eprint/27718/ http://umpir.ump.edu.my/id/eprint/27718/1/matecconf_ses2018_02005.pdf |
first_indexed |
2023-09-18T22:43:31Z |
last_indexed |
2023-09-18T22:43:31Z |
_version_ |
1777417072577347584 |