Effect of perforations on cold-formed steel built-up i-section

Cold-formed steel comes with various type of section based on their function and purpose in construction work. There are three main types of sections which are single open section, open built-up section and closed built-up section. This research will be concentrating on open built-up section or I-se...

Full description

Bibliographic Details
Main Author: Wan Mohamad Izzuan, Wan Kamaludin
Format: Undergraduates Project Papers
Language:English
Published: 2018
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/27804/
http://umpir.ump.edu.my/id/eprint/27804/
http://umpir.ump.edu.my/id/eprint/27804/7/Effect%20of%20perforations%20on%20cold-formed%20steel%20built-up.pdf
id ump-27804
recordtype eprints
spelling ump-278042020-02-11T07:50:26Z http://umpir.ump.edu.my/id/eprint/27804/ Effect of perforations on cold-formed steel built-up i-section Wan Mohamad Izzuan, Wan Kamaludin TA Engineering (General). Civil engineering (General) Cold-formed steel comes with various type of section based on their function and purpose in construction work. There are three main types of sections which are single open section, open built-up section and closed built-up section. This research will be concentrating on open built-up section or I-section. Structural members of cold-formed steel usually come with the presence of perforations. Perforations are a hole or opening that are made on the cold-formed steel to ease construction work. It usually provided with different shapes and size based on its function such as to accommodate electrical, plumbing and air conditioner or heating services. However, the presence of perforations may cause a reduction in strength of individual component elements and the overall strength of the member depending on the position, size and orientation of the opening. This research will focus on the effect of position and shape of the perforations on the structural strength of the axially loaded cold-formed steel column. An experimental investigation of cold-formed steel subjected to compression loading to study the effect of perforations on the load capacity of column members of built-up I-section is held. A total of 6 samples that have different position of perforations were tested in this experiment. Each member has nominal thickness of 1.2 mm, column length of 600 mm and was compressed between a simply supported ends at both end. The result of this experiment shows that the ultimate load of each sample varies greatly on the perforation position. The result is presented in three sections which are load vs vertical displacement, load vs horizontal displacement and buckling behavior. 2018-06 Undergraduates Project Papers NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/27804/7/Effect%20of%20perforations%20on%20cold-formed%20steel%20built-up.pdf Wan Mohamad Izzuan, Wan Kamaludin (2018) Effect of perforations on cold-formed steel built-up i-section. Faculty of Civil Engineering and Earth Resources, Universiti Malaysia Pahang. https://efind.ump.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=91002
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Wan Mohamad Izzuan, Wan Kamaludin
Effect of perforations on cold-formed steel built-up i-section
description Cold-formed steel comes with various type of section based on their function and purpose in construction work. There are three main types of sections which are single open section, open built-up section and closed built-up section. This research will be concentrating on open built-up section or I-section. Structural members of cold-formed steel usually come with the presence of perforations. Perforations are a hole or opening that are made on the cold-formed steel to ease construction work. It usually provided with different shapes and size based on its function such as to accommodate electrical, plumbing and air conditioner or heating services. However, the presence of perforations may cause a reduction in strength of individual component elements and the overall strength of the member depending on the position, size and orientation of the opening. This research will focus on the effect of position and shape of the perforations on the structural strength of the axially loaded cold-formed steel column. An experimental investigation of cold-formed steel subjected to compression loading to study the effect of perforations on the load capacity of column members of built-up I-section is held. A total of 6 samples that have different position of perforations were tested in this experiment. Each member has nominal thickness of 1.2 mm, column length of 600 mm and was compressed between a simply supported ends at both end. The result of this experiment shows that the ultimate load of each sample varies greatly on the perforation position. The result is presented in three sections which are load vs vertical displacement, load vs horizontal displacement and buckling behavior.
format Undergraduates Project Papers
author Wan Mohamad Izzuan, Wan Kamaludin
author_facet Wan Mohamad Izzuan, Wan Kamaludin
author_sort Wan Mohamad Izzuan, Wan Kamaludin
title Effect of perforations on cold-formed steel built-up i-section
title_short Effect of perforations on cold-formed steel built-up i-section
title_full Effect of perforations on cold-formed steel built-up i-section
title_fullStr Effect of perforations on cold-formed steel built-up i-section
title_full_unstemmed Effect of perforations on cold-formed steel built-up i-section
title_sort effect of perforations on cold-formed steel built-up i-section
publishDate 2018
url http://umpir.ump.edu.my/id/eprint/27804/
http://umpir.ump.edu.my/id/eprint/27804/
http://umpir.ump.edu.my/id/eprint/27804/7/Effect%20of%20perforations%20on%20cold-formed%20steel%20built-up.pdf
first_indexed 2023-09-18T22:43:36Z
last_indexed 2023-09-18T22:43:36Z
_version_ 1777417077924036608