Beam test of cold-formed steel built-up open section with different number and position of perforations

A cold-formed steel member include such products as purlins and girts for the construction of metal buildings, studs and joists for light commercial and residential construction, supports for curtain wall systems and also as a formed deck for the construction of floors and roof. Cold-formed steel co...

Full description

Bibliographic Details
Main Author: Nur Syahidah, Muhammad
Format: Undergraduates Project Papers
Language:English
Published: 2018
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/27835/
http://umpir.ump.edu.my/id/eprint/27835/
http://umpir.ump.edu.my/id/eprint/27835/1/Beam%20test%20of%20cold-formed%20steel%20built-up%20open%20section%20with%20different%20number%20and%20position.pdf
id ump-27835
recordtype eprints
spelling ump-278352020-02-13T02:35:44Z http://umpir.ump.edu.my/id/eprint/27835/ Beam test of cold-formed steel built-up open section with different number and position of perforations Nur Syahidah, Muhammad TA Engineering (General). Civil engineering (General) A cold-formed steel member include such products as purlins and girts for the construction of metal buildings, studs and joists for light commercial and residential construction, supports for curtain wall systems and also as a formed deck for the construction of floors and roof. Cold-formed steel comes with various type of section based on their function and purpose in construction work. This research will investigate the failure mode regarding the buckling behavior and the ultimate load of built-up cold-formed steel members with circular web holes. Structural members of cold-formed steel usually come with the presence of perforations. Perforation is a hole or opening that is made on the cold-formed steel to ease construction work. A total of 5 specimens with 20 mm holes diameters were tested under four-point bending test. The built-up open sections were assembled by self-tapping screws from either two lipped channels. Each member has nominal thickness of 1.2 mm, beam length of 1600 mm and supported with roller at both end. Reduction of ultimate loading and localized failure due to the presence of holes in the web plates of beams was observed in the tests. The result of this experiment shows that the ultimate load of each sample varies greatly on the number and position of perforation. The result is presented in two sections which are load vs displacement and buckling behavior. 2018-06 Undergraduates Project Papers NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/27835/1/Beam%20test%20of%20cold-formed%20steel%20built-up%20open%20section%20with%20different%20number%20and%20position.pdf Nur Syahidah, Muhammad (2018) Beam test of cold-formed steel built-up open section with different number and position of perforations. Faculty of Civil Engineering and Earth Resources, Universiti Malaysia Pahang. https://efind.ump.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=90893
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Nur Syahidah, Muhammad
Beam test of cold-formed steel built-up open section with different number and position of perforations
description A cold-formed steel member include such products as purlins and girts for the construction of metal buildings, studs and joists for light commercial and residential construction, supports for curtain wall systems and also as a formed deck for the construction of floors and roof. Cold-formed steel comes with various type of section based on their function and purpose in construction work. This research will investigate the failure mode regarding the buckling behavior and the ultimate load of built-up cold-formed steel members with circular web holes. Structural members of cold-formed steel usually come with the presence of perforations. Perforation is a hole or opening that is made on the cold-formed steel to ease construction work. A total of 5 specimens with 20 mm holes diameters were tested under four-point bending test. The built-up open sections were assembled by self-tapping screws from either two lipped channels. Each member has nominal thickness of 1.2 mm, beam length of 1600 mm and supported with roller at both end. Reduction of ultimate loading and localized failure due to the presence of holes in the web plates of beams was observed in the tests. The result of this experiment shows that the ultimate load of each sample varies greatly on the number and position of perforation. The result is presented in two sections which are load vs displacement and buckling behavior.
format Undergraduates Project Papers
author Nur Syahidah, Muhammad
author_facet Nur Syahidah, Muhammad
author_sort Nur Syahidah, Muhammad
title Beam test of cold-formed steel built-up open section with different number and position of perforations
title_short Beam test of cold-formed steel built-up open section with different number and position of perforations
title_full Beam test of cold-formed steel built-up open section with different number and position of perforations
title_fullStr Beam test of cold-formed steel built-up open section with different number and position of perforations
title_full_unstemmed Beam test of cold-formed steel built-up open section with different number and position of perforations
title_sort beam test of cold-formed steel built-up open section with different number and position of perforations
publishDate 2018
url http://umpir.ump.edu.my/id/eprint/27835/
http://umpir.ump.edu.my/id/eprint/27835/
http://umpir.ump.edu.my/id/eprint/27835/1/Beam%20test%20of%20cold-formed%20steel%20built-up%20open%20section%20with%20different%20number%20and%20position.pdf
first_indexed 2023-09-18T22:43:40Z
last_indexed 2023-09-18T22:43:40Z
_version_ 1777417081669550080