Kinetic study for biofilm manganese removal

Objective of this study is to determine the kinetic parameters of manganese (Mn) removal for the biofilm from two different sources; which were from drain and soil. There are four kinetic parameters needed to be determined which were yield coefficient (Y), decay rate constant (kd), microbial growth...

Full description

Bibliographic Details
Main Author: Nadzirah, Md Lazim
Format: Undergraduates Project Papers
Language:English
Published: 2010
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/3417/
http://umpir.ump.edu.my/id/eprint/3417/1/CD5937_NADZIRAH_BINTI_MD_LAZIM.pdf
id ump-3417
recordtype eprints
spelling ump-34172015-03-03T08:01:02Z http://umpir.ump.edu.my/id/eprint/3417/ Kinetic study for biofilm manganese removal Nadzirah, Md Lazim TD Environmental technology. Sanitary engineering Objective of this study is to determine the kinetic parameters of manganese (Mn) removal for the biofilm from two different sources; which were from drain and soil. There are four kinetic parameters needed to be determined which were yield coefficient (Y), decay rate constant (kd), microbial growth rate (µ), and substrate concentration (Ks); the calculation was based on Monod kinetic model. The process for determining kinetic parameters of each biofilm included the acclimatization of biofilm, total suspended solids tests (TSS), Mn tests and chemical oxygen demand (COD) tests. Sequencing batch biofilm reactor (SBR) is used in this study and two parameters are tested in the experiment; Mn and COD concentration. Results showed that the kinetic value for drain biofilm of Mn concentration parameter were Y = 2.9912 mg TSS/mg Mn, kd -1= 1.214 day, µmax -1= 1.374 daymax , and Ks = 0.4262 mg/L Mn. The soil biofilm for Mn concentration parameter showed the value of kinetic as Y = 0.1317 mg TSS/mg Mn, k d -1= 1.836 day, µmax -1= 1.846 day, and Ks = 0.0433 mg/L Mn. For the research on the COD concentration parameter, the values of kinetic for drain biofilm are Y = 0.0078 mg TSS/mg COD, kd -1= 1.0519 day, µ =1.136 daymax-1, and Ks = 4.403 mg/L COD. Soil biofilm showed the kinetic values of Y = 0.0117 mg TSS/mg COD, k= 1.8348 day-1, µmax -1 = 1.844 dayd , and Ks = 0.0433 mg/L COD. By the evaluation of COD and Mn removal from wastewater, from the way of kinetic parameter estimation provide knowledge for future planning, designing and modelling of wastewater treatment plant. 2010-04 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/3417/1/CD5937_NADZIRAH_BINTI_MD_LAZIM.pdf Nadzirah, Md Lazim (2010) Kinetic study for biofilm manganese removal. Faculty of Chemical & Natural Resources Engineering, Universiti Malaysia Pahang.
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TD Environmental technology. Sanitary engineering
spellingShingle TD Environmental technology. Sanitary engineering
Nadzirah, Md Lazim
Kinetic study for biofilm manganese removal
description Objective of this study is to determine the kinetic parameters of manganese (Mn) removal for the biofilm from two different sources; which were from drain and soil. There are four kinetic parameters needed to be determined which were yield coefficient (Y), decay rate constant (kd), microbial growth rate (µ), and substrate concentration (Ks); the calculation was based on Monod kinetic model. The process for determining kinetic parameters of each biofilm included the acclimatization of biofilm, total suspended solids tests (TSS), Mn tests and chemical oxygen demand (COD) tests. Sequencing batch biofilm reactor (SBR) is used in this study and two parameters are tested in the experiment; Mn and COD concentration. Results showed that the kinetic value for drain biofilm of Mn concentration parameter were Y = 2.9912 mg TSS/mg Mn, kd -1= 1.214 day, µmax -1= 1.374 daymax , and Ks = 0.4262 mg/L Mn. The soil biofilm for Mn concentration parameter showed the value of kinetic as Y = 0.1317 mg TSS/mg Mn, k d -1= 1.836 day, µmax -1= 1.846 day, and Ks = 0.0433 mg/L Mn. For the research on the COD concentration parameter, the values of kinetic for drain biofilm are Y = 0.0078 mg TSS/mg COD, kd -1= 1.0519 day, µ =1.136 daymax-1, and Ks = 4.403 mg/L COD. Soil biofilm showed the kinetic values of Y = 0.0117 mg TSS/mg COD, k= 1.8348 day-1, µmax -1 = 1.844 dayd , and Ks = 0.0433 mg/L COD. By the evaluation of COD and Mn removal from wastewater, from the way of kinetic parameter estimation provide knowledge for future planning, designing and modelling of wastewater treatment plant.
format Undergraduates Project Papers
author Nadzirah, Md Lazim
author_facet Nadzirah, Md Lazim
author_sort Nadzirah, Md Lazim
title Kinetic study for biofilm manganese removal
title_short Kinetic study for biofilm manganese removal
title_full Kinetic study for biofilm manganese removal
title_fullStr Kinetic study for biofilm manganese removal
title_full_unstemmed Kinetic study for biofilm manganese removal
title_sort kinetic study for biofilm manganese removal
publishDate 2010
url http://umpir.ump.edu.my/id/eprint/3417/
http://umpir.ump.edu.my/id/eprint/3417/1/CD5937_NADZIRAH_BINTI_MD_LAZIM.pdf
first_indexed 2023-09-18T21:57:42Z
last_indexed 2023-09-18T21:57:42Z
_version_ 1777414189828014080