Determination of glufosinate-ammonium and malathion in residue oil from palm pressed fiber using high performance liquid chromatography
A study on the determination of organophosphorus pesticides (OPPs), namely glufosinate-ammonium and malathion in residue from palm pressed fiber (PPF). Three PPF samples were taken from three different areas, FELDA Lepar, FELDA Chini 1 and FELDA Chini 2.The extraction of oil residue in PPF was car...
Main Author: | |
---|---|
Format: | Undergraduates Project Papers |
Language: | English |
Published: |
2012
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/7811/ http://umpir.ump.edu.my/id/eprint/7811/ http://umpir.ump.edu.my/id/eprint/7811/1/MUHAMMAD_HAZIQ_BIN_RUSSLI.PDF |
id |
ump-7811 |
---|---|
recordtype |
eprints |
spelling |
ump-78112018-10-17T03:37:54Z http://umpir.ump.edu.my/id/eprint/7811/ Determination of glufosinate-ammonium and malathion in residue oil from palm pressed fiber using high performance liquid chromatography Muhammad Haziq, Russli QP Physiology A study on the determination of organophosphorus pesticides (OPPs), namely glufosinate-ammonium and malathion in residue from palm pressed fiber (PPF). Three PPF samples were taken from three different areas, FELDA Lepar, FELDA Chini 1 and FELDA Chini 2.The extraction of oil residue in PPF was carried out using supercritical fluid extraction (SFE), using supercritical carbon dioxide (CO2) at 3000 psi in isothermal in 60°C for 60 minutes. Residue then were diluted uisng acetonitrile. Chromatogram of peak analyte was determine using Waters Alliance high performance liquid chromatography (HPLC) Dissolution System Series liquid chromatography interfaced to a 2998 Photodiode Array Detector. Determination was first done using standard malathion and glufosinate-ammonium of 10, 15 and 20 ppm run on a iscoratic elution mode for 30 minutes. Optimization method later was done using water and acetonitrile as mobile phase and run for 16 minutes for malathion and 20 minutes for glufosinate-ammonium. Malathion peak is retained at 8.0 minutes while glufosinate-ammonium at 16.0 minutes. Calibration curve of the standards were plot with R 2 values of 0.9085 for malathion and 0.9249 for glufosinate-ammonium. The detection limits (LOD) were 10.3 mg/L for malathion and 14.1 mg/L for glufosinate-ammonium. Later, determination of malathion and glufosinate-ammonium were done on real samples. For malathion determination, sample from Lepar showed to have concentraion of 19.46 ppm, Chini 1 (14.34 ppm) and Chini 2 (9.72 ppm). Determination of glufosinate-ammonium showed sample from Lepar to have concentraiton of 12.64 ppm, Chini 1 (17.72 ppm) and Chini 2 (39.64 ppm). 2012 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/7811/1/MUHAMMAD_HAZIQ_BIN_RUSSLI.PDF Muhammad Haziq, Russli (2012) Determination of glufosinate-ammonium and malathion in residue oil from palm pressed fiber using high performance liquid chromatography. Faculty of Industrial Sciences & Technology, Universiti Malaysia Pahang. http://iportal.ump.edu.my/lib/item?id=chamo:73275&theme=UMP2 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Malaysia Pahang |
building |
UMP Institutional Repository |
collection |
Online Access |
language |
English |
topic |
QP Physiology |
spellingShingle |
QP Physiology Muhammad Haziq, Russli Determination of glufosinate-ammonium and malathion in residue oil from palm pressed fiber using high performance liquid chromatography |
description |
A study on the determination of organophosphorus pesticides (OPPs), namely glufosinate-ammonium and malathion in residue from palm pressed fiber (PPF).
Three PPF samples were taken from three different areas, FELDA Lepar, FELDA Chini 1 and FELDA Chini 2.The extraction of oil residue in PPF was carried out using supercritical fluid extraction (SFE), using supercritical carbon dioxide (CO2) at 3000 psi in isothermal in 60°C for 60 minutes. Residue then were diluted uisng acetonitrile. Chromatogram of peak analyte was determine using Waters Alliance high performance liquid chromatography (HPLC) Dissolution System Series liquid chromatography interfaced to a 2998 Photodiode Array Detector. Determination was first done using standard malathion and glufosinate-ammonium of 10, 15 and 20 ppm run on a iscoratic elution mode for 30 minutes. Optimization method later was done using water and acetonitrile as mobile phase and run for 16 minutes for malathion and 20 minutes for glufosinate-ammonium. Malathion peak is retained at 8.0 minutes while glufosinate-ammonium at 16.0 minutes. Calibration curve of the standards were plot with R 2 values of 0.9085 for malathion and 0.9249 for glufosinate-ammonium. The detection limits (LOD) were 10.3 mg/L for malathion and 14.1 mg/L for glufosinate-ammonium. Later, determination of malathion and glufosinate-ammonium were done on real samples. For malathion determination, sample from Lepar showed to have concentraion of 19.46 ppm, Chini 1 (14.34 ppm) and Chini 2 (9.72 ppm). Determination of glufosinate-ammonium showed sample from Lepar to have concentraiton of 12.64 ppm, Chini 1 (17.72 ppm) and Chini 2 (39.64 ppm). |
format |
Undergraduates Project Papers |
author |
Muhammad Haziq, Russli |
author_facet |
Muhammad Haziq, Russli |
author_sort |
Muhammad Haziq, Russli |
title |
Determination of glufosinate-ammonium and malathion in residue oil from palm pressed fiber using high performance liquid chromatography |
title_short |
Determination of glufosinate-ammonium and malathion in residue oil from palm pressed fiber using high performance liquid chromatography |
title_full |
Determination of glufosinate-ammonium and malathion in residue oil from palm pressed fiber using high performance liquid chromatography |
title_fullStr |
Determination of glufosinate-ammonium and malathion in residue oil from palm pressed fiber using high performance liquid chromatography |
title_full_unstemmed |
Determination of glufosinate-ammonium and malathion in residue oil from palm pressed fiber using high performance liquid chromatography |
title_sort |
determination of glufosinate-ammonium and malathion in residue oil from palm pressed fiber using high performance liquid chromatography |
publishDate |
2012 |
url |
http://umpir.ump.edu.my/id/eprint/7811/ http://umpir.ump.edu.my/id/eprint/7811/ http://umpir.ump.edu.my/id/eprint/7811/1/MUHAMMAD_HAZIQ_BIN_RUSSLI.PDF |
first_indexed |
2023-09-18T22:04:49Z |
last_indexed |
2023-09-18T22:04:49Z |
_version_ |
1777414637956890624 |