Study on the improvement code of practices in structural design and material specifications

In Malaysia, most of the design concrete structure is based on Code of Practice British Standard (BS 8110). In line with the change of time and technology, Malaysia has been introduced to Eurocode 2 (EC 2) as a new guideline in design concrete structures. However, EC2 still in early stage of impleme...

Full description

Bibliographic Details
Main Author: Nurul Atiqah , Ajis
Format: Undergraduates Project Papers
Language:English
Published: 2012
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/7890/
http://umpir.ump.edu.my/id/eprint/7890/
http://umpir.ump.edu.my/id/eprint/7890/1/NURUL_ATIQAH_BINTI_AJIS.PDF
id ump-7890
recordtype eprints
spelling ump-78902015-03-03T09:38:42Z http://umpir.ump.edu.my/id/eprint/7890/ Study on the improvement code of practices in structural design and material specifications Nurul Atiqah , Ajis TH Building construction In Malaysia, most of the design concrete structure is based on Code of Practice British Standard (BS 8110). In line with the change of time and technology, Malaysia has been introduced to Eurocode 2 (EC 2) as a new guideline in design concrete structures. However, EC2 still in early stage of implementation therefore, it widely introduced to the engineers and in the higher institutions. The main objective of this study is to find the differences between BS 8110 and EC 2 in the aspect of materials and design specifications. There have few differences identified and studies have been conducted to find out the causes and reasons of the changing. The main differences between BS 8110 and EC 2 in the design specifications is BS 8110 designed based on structure element such as beam, column, slab and others. While, EC 2 designed based on phenomenon such as flexure, shear, deflection and axial force. In terms of material, there is change in partial factor of safety for reinforcing steel. Partial factor of safety for reinforcing steel in EC 2 is higher compare with value use in BS 8110. However, this difference neutralized by the reinforcing steel with f k = 500 N/mm 2 . In addition, there are many factors need to be consider in EC 2 compare with BS 8110. 2012-06 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/7890/1/NURUL_ATIQAH_BINTI_AJIS.PDF Nurul Atiqah , Ajis (2012) Study on the improvement code of practices in structural design and material specifications. Faculty of Civil and Environmental Engineering, niversiti Malaysia Pahang. http://iportal.ump.edu.my/lib/item?id=chamo:76497&theme=UMP2
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TH Building construction
spellingShingle TH Building construction
Nurul Atiqah , Ajis
Study on the improvement code of practices in structural design and material specifications
description In Malaysia, most of the design concrete structure is based on Code of Practice British Standard (BS 8110). In line with the change of time and technology, Malaysia has been introduced to Eurocode 2 (EC 2) as a new guideline in design concrete structures. However, EC2 still in early stage of implementation therefore, it widely introduced to the engineers and in the higher institutions. The main objective of this study is to find the differences between BS 8110 and EC 2 in the aspect of materials and design specifications. There have few differences identified and studies have been conducted to find out the causes and reasons of the changing. The main differences between BS 8110 and EC 2 in the design specifications is BS 8110 designed based on structure element such as beam, column, slab and others. While, EC 2 designed based on phenomenon such as flexure, shear, deflection and axial force. In terms of material, there is change in partial factor of safety for reinforcing steel. Partial factor of safety for reinforcing steel in EC 2 is higher compare with value use in BS 8110. However, this difference neutralized by the reinforcing steel with f k = 500 N/mm 2 . In addition, there are many factors need to be consider in EC 2 compare with BS 8110.
format Undergraduates Project Papers
author Nurul Atiqah , Ajis
author_facet Nurul Atiqah , Ajis
author_sort Nurul Atiqah , Ajis
title Study on the improvement code of practices in structural design and material specifications
title_short Study on the improvement code of practices in structural design and material specifications
title_full Study on the improvement code of practices in structural design and material specifications
title_fullStr Study on the improvement code of practices in structural design and material specifications
title_full_unstemmed Study on the improvement code of practices in structural design and material specifications
title_sort study on the improvement code of practices in structural design and material specifications
publishDate 2012
url http://umpir.ump.edu.my/id/eprint/7890/
http://umpir.ump.edu.my/id/eprint/7890/
http://umpir.ump.edu.my/id/eprint/7890/1/NURUL_ATIQAH_BINTI_AJIS.PDF
first_indexed 2023-09-18T22:05:00Z
last_indexed 2023-09-18T22:05:00Z
_version_ 1777414649258442752