To design rainwater collection system for domestic use and the economic cost analysis of the system

This thesis deals with the design of the rainwater collection system for domestic use and economic cost analysis of the system. The objective of this thesis are to design rainwater collection system and analyze the economic cost of the system for a family Pekan people. Rainwater are a natural source...

Full description

Bibliographic Details
Main Author: Lee, Kok Keong
Format: Undergraduates Project Papers
Language:English
Published: 2013
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/8600/
http://umpir.ump.edu.my/id/eprint/8600/
http://umpir.ump.edu.my/id/eprint/8600/1/CD8064_%40_96.pdf
id ump-8600
recordtype eprints
spelling ump-86002015-11-04T02:54:53Z http://umpir.ump.edu.my/id/eprint/8600/ To design rainwater collection system for domestic use and the economic cost analysis of the system Lee, Kok Keong TD Environmental technology. Sanitary engineering This thesis deals with the design of the rainwater collection system for domestic use and economic cost analysis of the system. The objective of this thesis are to design rainwater collection system and analyze the economic cost of the system for a family Pekan people. Rainwater are a natural source of clean water and suitable for non-portable use and solve the water shortage problem In this study, parameters of quality of rainwater were measured such as pH, turbidity, dissolve oxygen and total suspended solid. The finite element analysis was then performed using the software of Algor Simulation. The type of analysis was static stress with linear material model analysis against the structure stand of rainwater storage tank. The annual rainfall data of 2012 will be analyzed by software of Tanki Norm Simulation to find out the reliability of the rainwater collection system. In the result, all parameters of quality of rainwater measured were acceptable by refer from the table shown by Interim National Water Quality Standards For Malaysia ( Class IIB) except the level of dissolved oxygen was quite low compare with it. From the result of Tanki Nahrim Simulation, shown that the reliability of the system was 61.23 %. In economic aspect, it found out that the rainwater cost RM 3.1 per meter cube with five year payback period of the system which is higher than RM 0.37 per meter cube of pipe water. 2013-06 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/8600/1/CD8064_%40_96.pdf Lee, Kok Keong (2013) To design rainwater collection system for domestic use and the economic cost analysis of the system. Faculty of Mechanical Engineering , Universiti Malaysia Pahang. http://iportal.ump.edu.my/lib/item?id=chamo:83942&theme=UMP2
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TD Environmental technology. Sanitary engineering
spellingShingle TD Environmental technology. Sanitary engineering
Lee, Kok Keong
To design rainwater collection system for domestic use and the economic cost analysis of the system
description This thesis deals with the design of the rainwater collection system for domestic use and economic cost analysis of the system. The objective of this thesis are to design rainwater collection system and analyze the economic cost of the system for a family Pekan people. Rainwater are a natural source of clean water and suitable for non-portable use and solve the water shortage problem In this study, parameters of quality of rainwater were measured such as pH, turbidity, dissolve oxygen and total suspended solid. The finite element analysis was then performed using the software of Algor Simulation. The type of analysis was static stress with linear material model analysis against the structure stand of rainwater storage tank. The annual rainfall data of 2012 will be analyzed by software of Tanki Norm Simulation to find out the reliability of the rainwater collection system. In the result, all parameters of quality of rainwater measured were acceptable by refer from the table shown by Interim National Water Quality Standards For Malaysia ( Class IIB) except the level of dissolved oxygen was quite low compare with it. From the result of Tanki Nahrim Simulation, shown that the reliability of the system was 61.23 %. In economic aspect, it found out that the rainwater cost RM 3.1 per meter cube with five year payback period of the system which is higher than RM 0.37 per meter cube of pipe water.
format Undergraduates Project Papers
author Lee, Kok Keong
author_facet Lee, Kok Keong
author_sort Lee, Kok Keong
title To design rainwater collection system for domestic use and the economic cost analysis of the system
title_short To design rainwater collection system for domestic use and the economic cost analysis of the system
title_full To design rainwater collection system for domestic use and the economic cost analysis of the system
title_fullStr To design rainwater collection system for domestic use and the economic cost analysis of the system
title_full_unstemmed To design rainwater collection system for domestic use and the economic cost analysis of the system
title_sort to design rainwater collection system for domestic use and the economic cost analysis of the system
publishDate 2013
url http://umpir.ump.edu.my/id/eprint/8600/
http://umpir.ump.edu.my/id/eprint/8600/
http://umpir.ump.edu.my/id/eprint/8600/1/CD8064_%40_96.pdf
first_indexed 2023-09-18T22:06:21Z
last_indexed 2023-09-18T22:06:21Z
_version_ 1777414733753745408