Reliability analysis of multiphase flow measurements in different oil fields

The significant challenge in the oil and gas industry is the simultaneous measurement of commingled gas, oil, and water streams using separators or multiphase flow meters (MPFM). A major issue when using either test separator or MPFM in oil fields is the uncertainty of the measurements. The aim of...

Full description

Bibliographic Details
Main Authors: Ganat, Tarek A., Hrairi, Meftah, Hawlader, Mohammad Nurul Alam
Format: Article
Language:English
English
English
Published: EID-Energie informationsdients GmbH 2016
Subjects:
Online Access:http://irep.iium.edu.my/50902/
http://irep.iium.edu.my/50902/
http://irep.iium.edu.my/50902/1/Hrairi-OG133-16.pdf
http://irep.iium.edu.my/50902/2/Cover%2BTOC.pdf
http://irep.iium.edu.my/50902/12/50902_Reliability%20analysis%20of%20multiphase%20flow%20measurements%20in%20different%20oil%20fields_WOS.pdf
id iium-50902
recordtype eprints
spelling iium-509022017-06-05T01:26:00Z http://irep.iium.edu.my/50902/ Reliability analysis of multiphase flow measurements in different oil fields Ganat, Tarek A. Hrairi, Meftah Hawlader, Mohammad Nurul Alam TP690 Petroleum refining and products TP751 Gas industry The significant challenge in the oil and gas industry is the simultaneous measurement of commingled gas, oil, and water streams using separators or multiphase flow meters (MPFM). A major issue when using either test separator or MPFM in oil fields is the uncertainty of the measurements. The aim of this study is to compare three-phase test separator results with MPFM measurements by evaluating field test results from different oil fields in South East Asia, the Middle East, the Mediterranean region, and North Africa for a total of 41 oil wells from different oil fields. Generally, the results show wide variation of the liquid rate measurements between the conventional test separator and MPFM over several periods of time. Such differences, which can be caused by various conditions, become problematic since they impede the accurate estimation of a well’s output and add a degree of uncertainty to any plans to optimize production. A detailed review of each parameter is presented along with its sensitivities when determining the flow rates of oil, gas and water. To date, there are no sets of rules proving the technique for comparison between the test separator and the multiphase flow meter. EID-Energie informationsdients GmbH 2016-09 Article PeerReviewed application/pdf en http://irep.iium.edu.my/50902/1/Hrairi-OG133-16.pdf application/pdf en http://irep.iium.edu.my/50902/2/Cover%2BTOC.pdf application/pdf en http://irep.iium.edu.my/50902/12/50902_Reliability%20analysis%20of%20multiphase%20flow%20measurements%20in%20different%20oil%20fields_WOS.pdf Ganat, Tarek A. and Hrairi, Meftah and Hawlader, Mohammad Nurul Alam (2016) Reliability analysis of multiphase flow measurements in different oil fields. Oil Gas European Magazine, 42 (3). pp. 133-139. ISSN 0342-5622 http://oilgaspublisher.de/en/periodicals/
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
English
English
topic TP690 Petroleum refining and products
TP751 Gas industry
spellingShingle TP690 Petroleum refining and products
TP751 Gas industry
Ganat, Tarek A.
Hrairi, Meftah
Hawlader, Mohammad Nurul Alam
Reliability analysis of multiphase flow measurements in different oil fields
description The significant challenge in the oil and gas industry is the simultaneous measurement of commingled gas, oil, and water streams using separators or multiphase flow meters (MPFM). A major issue when using either test separator or MPFM in oil fields is the uncertainty of the measurements. The aim of this study is to compare three-phase test separator results with MPFM measurements by evaluating field test results from different oil fields in South East Asia, the Middle East, the Mediterranean region, and North Africa for a total of 41 oil wells from different oil fields. Generally, the results show wide variation of the liquid rate measurements between the conventional test separator and MPFM over several periods of time. Such differences, which can be caused by various conditions, become problematic since they impede the accurate estimation of a well’s output and add a degree of uncertainty to any plans to optimize production. A detailed review of each parameter is presented along with its sensitivities when determining the flow rates of oil, gas and water. To date, there are no sets of rules proving the technique for comparison between the test separator and the multiphase flow meter.
format Article
author Ganat, Tarek A.
Hrairi, Meftah
Hawlader, Mohammad Nurul Alam
author_facet Ganat, Tarek A.
Hrairi, Meftah
Hawlader, Mohammad Nurul Alam
author_sort Ganat, Tarek A.
title Reliability analysis of multiphase flow measurements in different oil fields
title_short Reliability analysis of multiphase flow measurements in different oil fields
title_full Reliability analysis of multiphase flow measurements in different oil fields
title_fullStr Reliability analysis of multiphase flow measurements in different oil fields
title_full_unstemmed Reliability analysis of multiphase flow measurements in different oil fields
title_sort reliability analysis of multiphase flow measurements in different oil fields
publisher EID-Energie informationsdients GmbH
publishDate 2016
url http://irep.iium.edu.my/50902/
http://irep.iium.edu.my/50902/
http://irep.iium.edu.my/50902/1/Hrairi-OG133-16.pdf
http://irep.iium.edu.my/50902/2/Cover%2BTOC.pdf
http://irep.iium.edu.my/50902/12/50902_Reliability%20analysis%20of%20multiphase%20flow%20measurements%20in%20different%20oil%20fields_WOS.pdf
first_indexed 2023-09-18T21:12:02Z
last_indexed 2023-09-18T21:12:02Z
_version_ 1777411316554661888