Selective harmonics elimination technique in single phase unipolar H -bridge inverter
Specific odd harmonics can be mitigated by operating the semiconductor switches in H-bridge inverters at optimized switching angles of the PWM signals. These switching angles can be achieved by deriving a set of nonlinear equations using Selective Harmonic Elimination Pulse Width Modulation (SHE-PWM...
Main Authors: | , , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English English |
Published: |
IEEE
2017
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/53995/ http://irep.iium.edu.my/53995/ http://irep.iium.edu.my/53995/ http://irep.iium.edu.my/53995/13/53995.pdf http://irep.iium.edu.my/53995/19/53995-Selective%20harmonics%20elimination%20technique%20in%20single%20phase%20unipolar%20H%20-bridge%20inverter_SCOPUS.pdf |
id |
iium-53995 |
---|---|
recordtype |
eprints |
spelling |
iium-539952017-06-15T02:14:09Z http://irep.iium.edu.my/53995/ Selective harmonics elimination technique in single phase unipolar H -bridge inverter Aboadla, Ezzidin Hassan Elmabrouk A Khan, Sheroz Habaebi, Mohamed Hadi Gunawan, Teddy Surya Hamida, Belal Ahmed Tohtayong, Majdee TK5101 Telecommunication. Including telegraphy, radio, radar, television Specific odd harmonics can be mitigated by operating the semiconductor switches in H-bridge inverters at optimized switching angles of the PWM signals. These switching angles can be achieved by deriving a set of nonlinear equations using Selective Harmonic Elimination Pulse Width Modulation (SHE-PWM) technique. Modulation index (ma) is a significant parameter used to control the amplitude of the fundamental output voltage of DC-AC inverter. By changing the value of modulation index the Total Harmonics Distortion (THD) also will change. In this paper, the performance of single phase H-bridge inverter using SHE-PWM scheme with varying the modulation index is evaluated. In order to achieve a minimum THD, a different number of nonlinear equations are used to calculate the switching angles. The performance of a single phase H-bridge inverter is simulated in Matlab-Simulink. IEEE 2017-01-09 Conference or Workshop Item PeerReviewed application/pdf en http://irep.iium.edu.my/53995/13/53995.pdf application/pdf en http://irep.iium.edu.my/53995/19/53995-Selective%20harmonics%20elimination%20technique%20in%20single%20phase%20unipolar%20H%20-bridge%20inverter_SCOPUS.pdf Aboadla, Ezzidin Hassan Elmabrouk A and Khan, Sheroz and Habaebi, Mohamed Hadi and Gunawan, Teddy Surya and Hamida, Belal Ahmed and Tohtayong, Majdee (2017) Selective harmonics elimination technique in single phase unipolar H -bridge inverter. In: 14th Student Conference on Research and Development, IEEE (SCOReD2016), 13th-14th December 2016, Kuala Lumpur. http://ieeexplore.ieee.org/document/7810057/ 10.1109/SCORED.2016.7810057 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
International Islamic University Malaysia |
building |
IIUM Repository |
collection |
Online Access |
language |
English English |
topic |
TK5101 Telecommunication. Including telegraphy, radio, radar, television |
spellingShingle |
TK5101 Telecommunication. Including telegraphy, radio, radar, television Aboadla, Ezzidin Hassan Elmabrouk A Khan, Sheroz Habaebi, Mohamed Hadi Gunawan, Teddy Surya Hamida, Belal Ahmed Tohtayong, Majdee Selective harmonics elimination technique in single phase unipolar H -bridge inverter |
description |
Specific odd harmonics can be mitigated by operating the semiconductor switches in H-bridge inverters at optimized switching angles of the PWM signals. These switching angles can be achieved by deriving a set of nonlinear equations using Selective Harmonic Elimination Pulse Width Modulation (SHE-PWM) technique. Modulation index (ma) is a significant parameter used to control the amplitude of the fundamental output voltage of DC-AC inverter. By changing the value of modulation index the Total Harmonics Distortion (THD) also will change. In this paper, the performance of single phase H-bridge inverter using SHE-PWM scheme with varying the modulation
index is evaluated. In order to achieve a minimum THD, a different number of nonlinear equations are used to calculate the switching angles. The performance of a single phase H-bridge inverter is simulated in Matlab-Simulink. |
format |
Conference or Workshop Item |
author |
Aboadla, Ezzidin Hassan Elmabrouk A Khan, Sheroz Habaebi, Mohamed Hadi Gunawan, Teddy Surya Hamida, Belal Ahmed Tohtayong, Majdee |
author_facet |
Aboadla, Ezzidin Hassan Elmabrouk A Khan, Sheroz Habaebi, Mohamed Hadi Gunawan, Teddy Surya Hamida, Belal Ahmed Tohtayong, Majdee |
author_sort |
Aboadla, Ezzidin Hassan Elmabrouk A |
title |
Selective harmonics elimination technique in single phase unipolar H -bridge inverter |
title_short |
Selective harmonics elimination technique in single phase unipolar H -bridge inverter |
title_full |
Selective harmonics elimination technique in single phase unipolar H -bridge inverter |
title_fullStr |
Selective harmonics elimination technique in single phase unipolar H -bridge inverter |
title_full_unstemmed |
Selective harmonics elimination technique in single phase unipolar H -bridge inverter |
title_sort |
selective harmonics elimination technique in single phase unipolar h -bridge inverter |
publisher |
IEEE |
publishDate |
2017 |
url |
http://irep.iium.edu.my/53995/ http://irep.iium.edu.my/53995/ http://irep.iium.edu.my/53995/ http://irep.iium.edu.my/53995/13/53995.pdf http://irep.iium.edu.my/53995/19/53995-Selective%20harmonics%20elimination%20technique%20in%20single%20phase%20unipolar%20H%20-bridge%20inverter_SCOPUS.pdf |
first_indexed |
2023-09-18T21:16:23Z |
last_indexed |
2023-09-18T21:16:23Z |
_version_ |
1777411590742605824 |